INSTALLATION: The sheathing that connects the external to the internal unit may pass: a) through a slightly open window or door;
b) through a small hole (5.5cm x 2.5cm) drilled in the lower part of a door or in a window frame by using the frame provided.
USE OF RAPID COUPLINGS In addition to the methods described above, the sheathing that joins the external to the internal unit may also be drawn through a hole (about 6cm in diameter) drilled in a wall linked to the outside. In this case, the hook-ups with the external unit must be disconnected as follows: 1) Remove the plug from the electric outlet; 2) Remove the handle by loosening the two screws and then slipping off the facing.
3) Remove the u bolt by loosening the two screws. 4) Remove the sheath stop by loosening the two screws. 5) Using a 24-version wrench, unscrew the union on the coupling. At the same time, hold the end of the flexible tube tight by using a 21 version wrench. Repeat this operation for the second union using a 24- and a 19-version wrench.
6) Disconnect the condensation tube from the rubber holder. 7) Loosen the shield's two self-threading screws and disconnect the electric hook-up unit. The path of the connecting sheath should be as straight as possible, without sharp curves or kinks. To re-connect the detached ends of the sheath to the internal unit, you must repeat operations 1 through 7 in reverse order, being careful to observe the following precautions:
Caution: We recommend that the disconnecting and connecting of the rapid couplings be carried out only by qualified technicians. INTERNAL UNIT Install the internal unit inside the room to be air conditioned. This is usually done under a window or at least close to an outside wall. The internal unit must be placed "on the level" with the help of castor-stops provided. No obstacles should block this units in-take (suction grille) or out-take (outlet grille) areas. EXTERNAL UNIT The external unit may be placed on a terrace or balcony, in which case the brackets need not be used.
The external unit can be attached to a wall with the accessories included as follows: 1) Attach the bracket to the wall while taking care to place it as indicated in the drawing. Use the included template located on the plastic cover in order to drill the holes. 2) Screw the support blocks to the external unit with the included M4mm screws while taking care to place it as indicated template located on the plastic cover in order to drill the holes. 3) Attach the external unit to the bracket by means of M6mm.
For temporary installation it is possible to hang the external unit as illustrated in the drawing. In this case, use the included straps by attaching them to the eye hooks. Before inserting the eye hooks remove the rubber plugs.
The external unit may be installed above or at the same height as the internal unit, on the condition that the difference is no more than 1.5m. The suction and air delivery portions of external unit must not be blocked by obstacles of any nature. The distance between the back of the appliance and the wall must be 6cm. The condensation which forms while this application is running (summertime operations) is disposed of by evaporation from the external unit. If the humidity is too high (in special cases) you must use the drainage coupling provided to get rid of condensation. This device must be mounted on the bottom of the external unit (see drawing) after the rubber plug has been removed. We strongly recommend that you protect the external unit from rain, snow, direct sunlight and water dripping from the roof.
|
|