Features:
Integral Sump with in-built water level control sensor
Pump
Head of 6 metres
Will
move up to 6 Litres / Hour
Suction lift up to 2 metres (max)
Will
remove up to 35,000 btu/hr (sensible cooling)
condensate
water from air conditioners
Built in non-return valve
Can
be installed in wall, ceiling and floor mounted split systems.
Installation Guide:
The
pump units are intended to be screw fixed within a ceiling
void, but may be installed
surface mounted if no ceiling void
exists in PVC trunking.
The
Standard model pump, sump and suction tube can be
concealed within 100 mm x 50 mm PVC
trunking.
It may be
possible with certain units to conceal the sump in the
fan coil. When mounting the sump
integrally the engineer may
need to fit a `Terrain Tank Connector'
(not supplied) into the side
of the sump (see figures 2 & 3).
To do this
drill a 22 mm hole into an appropriate place in the
sump and use a suitable fitting.
The pump
is self priming, although the pump lift should be kept to
a minimum (2 metres or less) to reduce
pump noise.
It should
be noted that on initial start up, the pump may be noisy
for a few seconds until the pump is
primed.
The pump
has a non-return valve incorporated to prevent `water
run back`.